TS3311 Indicator
The indicator tells you which section drifted
At an indoor desk, the operator runs inbound and outbound weighing from a 7-inch color screen with 7/8-inch digits, a numeric keypad and five function buttons. It keeps 1,000 customer and 1,000 product records, loaded from a spreadsheet, and accumulates product inventory against each weighment. Tickets print on the site's own layout. If a load cell fails, the Intalogix® diagnostics page shows which one with a timestamped error code, so service goes straight to it.
Analog signals digitize at scale-mounted Smart Sectional Controllers, two cells each, one per section, with surge protection in the digital signal path. The home run travels digitally, as far as 1,800 ft on ten 1,000-ohm cells. The controllers and pit power supply are ordered separately. The NEMA 12 desktop has two RS-232, a 20 mA loop, two USB and Ethernet standard.
Features & benefits
Intalogix® digital load-cell interface
Analog cells digitize at Smart Sectional Controllers, two cells per SSC, one SSC per scale section.
Cell-by-cell trim, calibration and diagnostics
Names the failing load cell with a timestamped error code instead of isolating by elimination.
Home run to 1,800 ft on ten 1,000-ohm cells
Puts the scale house well off the deck; a second pit power supply doubles the distance.
Embedded web server
Configure, pull transaction reports and lay out tickets from a browser on the plant network.
7-inch 800 x 480 color display, 7/8-inch digits
Numeric keypad plus five function buttons; brightness set from the operator menu.
Gross-Tare-Net and inbound/outbound weighing modes
One indicator covers bench, floor, hopper, truck and rail work without a firmware change.
Standard Ethernet, dual RS-232, 20 mA and dual USB
Networks, remote displays, printers and a USB keyboard connect without buying an option card.
1,000 customer and 1,000 product records, CSV import
Bulk-load records from a spreadsheet and accumulate product inventory against each weighment.
What's included
- TS3311 NEMA 12 desktop indicator (PN 40294)
- AC power cable
From each load cell to the TS3311
- Analog load cells of any brand, a pair in every section. A failed cell is replaced from general stock, not from a proprietary digital line.
- One Smart Sectional Controller per section, serving its two cells, digitizes each load cell signal at the scale.
- The controllers daisy-chain on one digital path to the scale house.
- One pit power supply per scale, with built-in lightning and surge protection.
- The TS3311 reads each load cell and section. Technicians trim cell by cell, and the diagnostics page names the failing cell.
Detail A. Each cell's signal enters its controller as analog and leaves as digital data, so the indicator sees every cell on its own. The controllers and the pit power supply are ordered separately from the indicator.
Analog signal Digital data
The technical picture
The TS3311 reaches the scale over Intalogix® digital load-cell communication. Analog signals digitize at scale-mounted Smart Sectional Controllers, two cells each, one per section. The home run then travels digitally, up to 1,800 ft on ten 1,000-ohm cells. Technicians trim cell by cell, and the diagnostics page names the failing cell.
The desktop housing is an aluminum base with a powder-coated mild steel cover, rated NEMA 12 and 14 F to 104 F (-10 C to 40 C) for indoor installation. The display is a 7-inch 800 x 480 color LCD. Standard comms are two RS-232 ports, a 20 mA loop, two USB ports and a 10/100 Base-T Ethernet port; one expansion slot takes an accessory card.
An embedded web server puts configuration, live weight, transaction reports, drag-and-drop ticket layout and CSV record import in a browser on the same network. Storage holds 1,000 tares and 10,000 transactions. NTEP CC 25-080, class III/IIIL.
At a glance
| Series | TS3300 |
|---|---|
| Form Factor | Desktop |
| Enclosure / Material | Aluminum base, powder-coated mild steel cover |
| NEMA Rating | NEMA 12 |
| Connectivity / Comms | Ethernet TCP/IP (std), RS232, USB, 20 mA, PLC interfaces |
| Intalogix Option | Yes |
| Key Features | Intalogix digital load-cell comms + surge protection; web server; diagnostics |
| Certifications and standards |
|
Complete specifications are in the product documents below. Confirm current figures with your distributor before specifying.
Options & accessories
Item numbers and availability are confirmed at quotation. Ask your distributor to verify configuration and compatibility before ordering.
Order at purchase Factory or order time
NEMA 4 USB keyboard
Wireless Ethernet bridge / access point5 GHz
AC power required at each point. 38914 is a single unit.
Added in the field Order any time
Smart Sectional ControllerStainless steel NEMA 4X
Required for each section of a truck scale or each pair of load cells. Not included with the indicator. Excitation 6.3 VDC.
Pit power supplyRequired to power Smart Sectional Controllers
Required to power the SSCs and not included with the indicator. An additional supply is required above 16 load cells.
Intalogix conversion package1 to 8 sections
Field retrofit of an existing scale. Includes 70 ft of 17245 cable, one SSC per section, one 32163 pit power supply and one 23143 surge protection box.
Self-contained Intalogix enclosure2 / 3 / 4 / 5 section
Houses the SSC boards and one pit power supply board with internal interconnects in a stainless NEMA 4X enclosure.
Intalogix approved home-run cable6-conductor shielded pairs
17245 adds a stainless overbraid. Home-run length must not exceed the limit for the cell count and resistance.
SSC interface cable31 ft / 40 ft pre-cut
4-20 mA analog output cardPassive, 16-bit
Requires an isolated, dedicated power supply; one supply per 4-20 mA module. Most PLC power supplies are not isolated. External 24 VDC supply 29560 available.
24 VDC external power supply for the passive 4-20 mA card
Required with item 30919 only. Wall transformer, 120 VAC to 220 VAC, 0.75 A.
4-20 mA analog output cardActive, 16-bit
Enhanced analog output card
Active device, powered by the indicator. Selectable ranges 0-5 V, 0-5.5 V, +/-5 V, +/-5.5 V, 0-10 V, +/-10 V, 0-11 V, +/-11 V, 0-20 mA, 0-24 mA and 4-20 mA.
Relay box interface card
Required to connect the 713 relay box or the ACC 778 LED traffic light. Not required when using a 218T and controlling lights over the 20 mA interface.
Serial expansion cardFour ports
Port 1 RS-232 with full modem support; port 2 RS-232 or 20 mA; port 3 RS-232 or RS-422 jumper-selectable; port 4 RS-485 only.
Ethernet/IP PLC interface card
PLC-style interface, not for PC interfaces. Provides weight data only. Card guides not required and not included. Occupies the single expansion slot.
Modbus TCP PLC interface card
Provides weight and load-cell status only. Card guides not required and not included. Occupies the single expansion slot.
DeviceNet PLC interface card
Provides weight and load-cell status only. Card guides not required and not included. Occupies the single expansion slot.
External Ethernet (RJ45) connectorNEMA 4
External USB connectorNEMA 4
Manual Table 2-1 prints this part number as 362411 (six digits); treat as a typographical error pending confirmation.
Pass-through gland nut
87-key USB QWERTY keyboard
An external keyboard is required to add or edit text records from the front panel.
713 Series relay boxDry contact
One relay, controls one traffic light. Requires relay box interface card 30920 and box-to-indicator cable 17216.
Specifier & operator FAQ
Is the TS3300 legal for trade in the United States?
Yes. NTEP Certificate of Conformance 25-080 covers Model TS3300 as a digital electronic indicating element, accuracy class III / III L, n_max 10,000, issued 27 August 2025. The certificate lists both the analog and Intalogix variants and both housings. In Canada, the TS3300 is covered by Measurement Canada class approval AM-6004. NTEP and Measurement Canada are separate approvals and neither implies the other.
Does the TS3311 work with standard analog load cells?
Yes. Intalogix digitizes the output of conventional analog load cells at the Smart Sectional Controllers; no proprietary digital load cells are required. Each SSC serves two load cells, normally one SSC per scale section. The SSCs and the pit power supply are ordered separately from the indicator and are not included with it.
What can you do from the web interface?
Enter the indicator IP address in a browser on the same network. Without a password you see live scale weight, the operator menu and the audit trail. The customer or service password adds full configuration and the drag-and-drop ticket editor. It also opens transaction reports, tare management, CSV import and export of customer and product records, and the cell diagnostics page.
Which communications are standard and which cost extra?
Standard on every unit: two RS-232 ports, one optically isolated 20 mA loop, two USB ports, one dedicated RS-485 relay-box output and one 10/100 Base-T Ethernet port. Separately priced field-installed cards for the single expansion slot cover extra serial ports and RS-485, 4-20 mA and voltage analog output, and Ethernet/IP, Modbus TCP or DeviceNet PLC interfaces.
How many load cells will it run?
Sixteen 1,000-ohm load cells or ten 350-ohm load cells on one scale. The indicator handles one scale. Load cell capacity has no practical limit; scale capacity is configurable from 0 to 999,999 with division sizes from 0.0001 to 200 and resolution of 10,000d commercial or 50,000d non-commercial.
What printers and remote displays does it drive?
The 295 and 590 Series ticket printers, the TM-T88VII thermal printer over USB, and the 220 tape printer — the T88VII and 220 print accumulation records. Remote displays: the 218 Series 1.5-inch and 5-inch LED displays, the 218T with integrated traffic light, and the 218 RF. Ethernet output supports continuous, print-triggered and polled modes.
Manuals & literature
Operator manual · IndicatorsDownload
Operator manual · IndicatorsDownload
In the same family

TS3301 Desktop Indicator
Rugged, web-enabled analog weighing indicator with advanced functionality.

TS600 Desktop Indicator
TS601 / TS611Desktop vehicle-weighing indicator with three operating modes, built-in traffic controls and transaction export.

TS600 Driver Assist Terminal
TS600 DATSelf-service driver terminal letting drivers self-weigh from the vehicle to speed throughput and cut cost.